60200FR Flame Rod Microprocessor Gas Primary Control

 

 

 

Features & Benefits
  Interrupted Duty Ignition
    Recycle on Flame Failure
    Serviceman Reset Protection ( Latch-up after three consecutive lockouts)
    Diagnostic & Flame Indicator LED’s
    Pre-Purge and Post-purge (contact Carlin for available timings)
    2 Second Ignition Establishment Period
    4 Second Trial for Ignition (TFI) Other Timings Available
    1.3 Second Flame Failure response time (FFRT)
    Alarm Contacts
    Thermostat/aquastat Compatible
    SMC (Safety Monitoring Circuit) Technology

Power
Input

(Red/White Wire)

120 vac, 60 Hz, 9 VA

Limit
Circuit Input

(Black Wire)

120 vac, 60 Hz
Motor
Load
120 vac, 60 Hz, 10
FLA, 60 LRA
Ignitor
Load
120 vac, 60 Hz, 500 VA
Valve
Load
120 vac, 60 Hz, 2.0 Amps
Alarm
Contacts
24V, AC/DC, 2 Amps
Operating
Temperature Limits
+32°F to + 140°F
Storage
Temperature Limits
-40°F to +185°F
Thermostat
Anticipator Current
0.2A, AC
Flame Current (Minimum)
0.8 Microamp DC
Wiring
Diagram
Agencies
UL Recognized (US), CUL Recognized (Canada)